Skip to main content
Figure 7 | Heritage Science

Figure 7

From: Fine particulate matter in indoor cultural heritage: a literature review

Figure 7

Leakage through cracks. Comparison of deposition and penetration through cracks and leaks obtained with the Nazaroff equations for deposition and leakage. Note that the particles with smaller deposition rates also penetrate through cracks more efficiently. Crack dimensions: width = 0.20 mm, length = 4 cm, pressure difference = 4 Pa, air flow conditions: K = 0.5, cubic room (3x3x3 m). All values taken as representative of realistic cracks by [62].

Back to article page