Skip to main content

Table 1 Comparison of different imaging modalities

From: An assessment of multimodal imaging of subsurface text in mummy cartonnage using surrogate papyrus phantoms

Imaging technique

Number of sheets through which iron-based inks can be recorded

Number of sheets through which carbon-based inks can be recorded

Typical image acquisition time

Typical image processing time

Pixel/voxel size

Field of view

Multispectral imaging

2

2

20 min

~ 1 h

24 μm

30 × 30 cm

Transillumination

> 3

> 3

20 min

~ 1 h

24 μm

10 × 15 cm

Optical coherence tomography

0

0

< 10 s

2 min

2 μm

10 mm × 2 mm (in depth)

X-ray micro tomography

> 3

Not visible

18 h

< 2 h

38 μm

5 × 10 cm

Portable X-ray fluorescence spectroscopy

6

Not visible

30 s

None

~ 1 cm

1 cm

X-ray fluorescence imaging

> 3

Not visible

10 s

1 min

100 μm

10 × 15 cm

X-ray phase contrast imaging

> 3

Not visible

10 min

1 min

100 μm

2 × 5 cm

Terahertz

1

3

0.1 s/pixel

10–20 s

100 μm

4 × 4 cm

  1. Note that for most of these parameters can be varied depending on the application, so these figures should be seen as indicative only