Skip to main content

Table 1 Fitting parameters for the 19 chimneys

From: Flow analysis of a set of ornamental chimney caps designed by Antoni Gaudí

Chimney number

Orientation

\(\left( {1 - K^{2} } \right)\)

\(K\)

\(R^{2}\)

1

O1

− 1.97

1.72

0.996

O2

0.44

0.75

0.930

2

O1

− 1.82

1.68

0.994

O2

0.01

0.99

< 0

3

O1

− 1.67

1.64

0.991

O2

− 0.13

1.06

< 0

4

O1

− 1.69

1.64

0.999

O2

− 0.12

1.06

0.816

5

O1

− 2.00

1.73

0.997

O2

− 0.95

1.40

0.975

6

O1

− 2.31

1.82

0.998

O2

− 0.78

1.33

0.983

7

O1

− 0.29

1.13

0.954

O2

− 0.02

1.01

< 0

8

O1

− 0.49

1.22

0.974

O2

− 1.05

1.43

0.958

9

O1

− 1.00

1.41

0.989

O2

− 0.61

1.27

0.853

10

O1

− 1.04

1.43

0.985

O2

− 0.61

1.27

0.922

11

O1

− 0.87

1.37

0.965

O2

− 1.30

1.52

0.991

12

O1

− 1.24

1.50

0.987

O2

− 0.94

1.39

0.991

13

O1

− 1.10

1.45

0.981

O2

− 0.91

1.38

0.962

14

O1

− 1.08

1.44

0.999

O2

− 1.92

1.71

0.998

15

O1

− 1.00

1.42

0.997

O2

− 1.46

1.57

0.989

16

O1

− 1.31

1.52

0.963

O2

− 1.50

1.58

0.993

17

O1

− 1.49

1.58

0.999

O2

− 1.35

1.53

0.991

18

O1

− 1.68

1.64

0.998

O2

− 2.06

1.75

0.999

19

O1

− 1.58

1.61

0.999

O2

− 1.73

1.65

0.999