Skip to main content

Table 4 Test conditions of active-mode tests (with forced air exchange)

From: Adsorbent media for the sustainable removal of organic air pollutants from museum display cases

Parameters

Adjustment/procedure

Chamber volume [m3]

1

Adsorbent weight [g]

ca. 3

Temperature [°C]

30 ± 2

Relative humidity [%]

50 ± 5

Air exchange rate [h−1]

0.5

Testing time [h]

72

Injected target substances [mg/ml]

Para-formaldehyde: 12 mg

Acetic acid, formic acid, toluene, alpha-pinene: 10 ml

Sampling intervals [h]

5, 24, 30, 48, 72

Sampling VOCs

Adsorbent: Tenax TA®, sampling volume: 3 l, analysis: TD-GC/MS

Sampling formaldehyde

Adsorbent: distilled water, sampling volume: 30 l, analysis: acetylacetone-fluorescence

Sampling formic acid and acetic acid

Adsorbent: silica gel, sampling volume: 30 l, analysis: IC