Skip to main content

Table 2 Parameters for simulated materials

From: Artificial lightning strike tests and coupled electrical–thermal analysis on roofing glazed tiles of ancient buildings

Material type Density
kg/m3
Elastic modulus
GPa
Poisson’s ratio Thermal expansion coefficient Thermal conductivity W/(m·K) Specific heat J/kg Conductivity
S/m
Body 3980 370 0.22 6.8 × 10−6 20 880 8 × 10−8
Mortar 1600 30 0.2 8 × 10−6 0.81 970 0.6