Skip to main content

Table 1 Studies explaining the rationale behind the deployment of measuring points for indoor climate monitoring.

From: Strategies for the deployment of microclimate sensors in spaces housing collections

Refs.

Type of spaces housing collections

Indoor climate variables

Methodology for sensors deployment

[9]

Archaeological site

T, RH

Thermographic measurements

[10]

Castle

T, RH

Adoption of well-established criteria [6], Table 2

[11]

Church

T, RH, Ts, V

[12]

Monastery

T, RH, CO2

[13]

Library

T, RH

Microclimate measurement campaigns on 2-D virtual grid

[14]

Museum

T, RH

Signal propagation and coverage of wireless sensors

[15]

Palaces

T, RH

[16]

Archaeological site

T, RH, E, CO2, O2

Sampling Design method

[17]

Cathedral

T, RH

Microclimate measurement campaigns on 3-D virtual grid

[18]

Temple

T, RH, V

Lowest aesthetic impact, measuring points easily reachable

[19]

Gallery

T, RH

[20]

Palace

T, RH, Ts

Restoration theories

[21]

Gallery

T, RH, Ts, CO2

[22]

Museum

T, RH

Multivariate statistics to optimise the current measuring points

[23]

Cathedral

T, RH

[24]

Castle/Museum

T, RH

  1. CO2 carbon dioxide concentration, E irradiance, O2 oxygen concentration, RH relative humidity, T temperature, Ts surface temperature, and V air flow