Skip to main content

Table 3 Average values of RH and T for each cycle, calculated starting within 3 h from the RH change applied until the next change and their standard deviations

From: Hygromechanical behaviour of wooden panel paintings: classification of their deformation tendencies based on numerical modelling and experimental results

Test name

Average ΔRH [%]

Sd RH [%]

Average T [°C]

Sd T [°C]

ADS 1

Not waterproofed

52–61

 ± 0.2

25.5

 ± 1.0

ADS 2

Not waterproofed

51–60

 ± 0.1

20.7

 ± 1.1

ADS 3

Waterproofed

53–60

 ± 0.1

20.6

 ± 0.4

DES 1

Not waterproofed

62–52

 ± 0.4

25.4

 ± 0.5

DES 2

Not waterproofed

61–56

 ± 0.2

24.8

 ± 1.1

DES 3

Not waterproofed

56–51

 ± 0.3

23.5

 ± 1.0

DES 4

Waterproofed

60–53

 ± 0.3

20.7

 ± 0.5