Skip to main content

Table 1 List of laboratory samples and their dimensions, average, standard deviation values of Vp (m/s), R (−), UCS (MPa) measured and description of degradation phenomena

From: Non-destructive methods applied for in situ mechanical diagnosis: Florentine historical buildings in Pietra Serena

Name of slabs

N. of samples

Vp (m/s)

R (-)

UCS (Mpa)

Description

P01

4

2420 ± 130

37 ± 3

52 ± 10

Compact stone in good condition

P02

4

2420 ± 110

32 ± 6

44 ± 5

Partial disintegration and exfoliation

P03

4

2870 ± 510

34 ± 2

41 ± 6

Partial delamination and presence of lichens

P04

3

1630 ± 250

23 ± 9

8 ± 0

Strong delamination, erosion, cracks, biological colonization

P05

5

2640 ± 80

28 ± 4

35 ± 2

Partial delamination, deposit

P06

4

2730 ± 130

34 ± 2

56 ± 5

Partial exfoliation, deposit, disintegration

P07

4

2720 ± 160

33 ± 3

53 ± 7

Delamination, erosion

P08

3

3130 ± 60

35 ± 1

71 ± 13

Compact stone in good condition

P09

8

3410 ± 110

40 ± 4

116 ± 19

Compact stone in good condition

P10

6

500 ± 140

22 ± 2

12 ± 2

Strong erosion, cracks