Skip to main content

Table 2 Statistical metrics of UCS-Vp, UCS-R and UCS-R-Vp, exponential models and non linear model, respectively

From: Non-destructive methods applied for in situ mechanical diagnosis: Florentine historical buildings in Pietra Serena

Model

R2

RMSECV (% RMSECV)

MAPECV (%)

UCS = 4.5004 * e0.000905Vp

0.72

16.32 (28)

35

UCS = 2.11 * e0.0944*R

0.73

13.81 (23)

37

UCS = 1.105R + 1.001Vp − 2.51

0.86

9.95 (17)

24