From: Non-destructive methods applied for in situ mechanical diagnosis: Florentine historical buildings in Pietra Serena
Model
R2
RMSECV (% RMSECV)
MAPECV (%)
UCS = 4.5004 * e0.000905Vp
0.72
16.32 (28)
35
UCS = 2.11 * e0.0944*R
0.73
13.81 (23)
37
UCS = 1.105R + 1.001Vp − 2.51
0.86
9.95 (17)
24