Table 1 Acquisition parameters of the scan of case study 1: “Green velvet purse”

From: Beam filtration for object-tailored X-ray CT of multi-material cultural heritage objects

 

Scan 1

Scan 2

Scan 3

Scan 4

Scan 5

Scan 6

Beam parameters

 Tube voltage

\({50}\,\hbox {kV}\)

\({50}\,\hbox {kV}\)

\({75}\,\hbox {kV}\)

\({75}\,\hbox {kV}\)

\({75}\,\hbox {kV}\)

\({75}\,\hbox {kV}\)

 Tube current

\({700}\,\upmu {\hbox {A}}\)

\({700}\,\upmu {\hbox {A}}\)

\({200}\,\upmu {\hbox {A}}\)

\({1000}\,\upmu {\hbox {A}}\)

\({1000}\,\upmu {\hbox {A}}\)

\({1000}\,\upmu {\hbox {A}}\)

      

Sn \({0.25}\,\hbox {mm}\)

      

Cu \({0.5}\,\hbox {mm}\)

 Filters

None

Al \({0.5}\,\hbox {mm}\)

None

Cu \({0.5}\,\hbox {mm}\)

Sn \({0.25}\,\hbox {mm}\)

Al \({0.5}\,\hbox {mm}\)

Camera settings

 Exposure time

200 \(\hbox {ms}\)

 Nr. of projections

2881

 Nr. of averages

1

Geometry

 Source-Object-Distance (SOD)

447 \(\hbox {mm}\)

 Source-Detector-Distance (SDD)

609 \(\hbox {mm}\)

 Object voxel size

54.9 \(\upmu \hbox {m}\)