Skip to main content

Table 6 Computational values of defect 3

From: Simulation-aided infrared thermography with decomposition-based noise reduction for detecting defects in ancient polyptychs

 

Defect 3

sound area

MC of raw image of sample A:

0.45

0.46

MC of processed image of sample A:

0.27

0.34

HFM of raw image of sample A:

3.76 \(\times\) 10–7

2.51 \(\times\) 10–7

HFM of processed image of sample A:

2.96 \(\times\) 10–6

1.18 \(\times\) 10–6

HS of raw image of sample A:

0.06

0.08

HS of processed image of sample A:

0.09

0.04

MC of raw image of sample B:

0.08

0.05

MC of processed image of sample B:

0.23

0.21

HFM of raw image of sample B:

4.98 \(\times\) 10–7

5.31 \(\times\) 10–7

HFM of processed image of sample B:

1.84 \(\times\) 10–6

3.97 \(\times\) 10–6

HS of raw image of sample B:

0.06

0.05

HS of processed image of sample B:

0.04

0.06