Table 3 Glassware cleaning procedures of metal coupons used by each participating institution in the interlaboratory comparison of the 3-in-1 Oddy test

From: Review and interlaboratory comparison of the Oddy test methodology

Participants

Detergent used for glassware cleaning

I

New glassware was used and hand washed with a 2% solution of Decon 90 in deionized water. The test tubes remained submerged in the solution for several hours, ensuring that no air bubbles were trapped in the tubes. Then rinsed in distilled water overnight and subsequently rinsed again in distilled water several more times. Finally washed with technical grade ethanol

II

New glassware was used. It was rinsed with a 0.1% solution of ZVG Washing up liquid HS 50420–010 in tap water. Then rinsed again several times (until no bubbles were formed) with demineralized water, air-dried, rinsed with pure ethanol and finally air dried

III

New glassware was used for this experiment, all Erlenmeyer flask were rinsed with deionized water and dried in the oven overnight

IV

Schott glassware and caps were washed with detergent in warm water (Deconex 20 NS-x, 250 mL per 10 L water, submerged in a tub), rinsed with tap water, deionized water and MQ water. All pieces were ultrasonicated for 15 min in MQ water and dried in an oven at 110 °C for 16 h

Silicone stoppers were rinsed with deionized water and left to air dry. Three incisions were cut into each stopper with a scalpel

V

New glassware was used and glassware was manually cleaned with Alconox (1%) detergent. A sponge was dedicated for washing Oddy testing glassware. Glassware was rinsed with deionized water several times and finally washed with ACS acetone. All containers were air-dried completely

VI

Schott glasses, caps, glass vials and silicone stoppers were left to soak in a 5% Decon 90/DI water solution for 4 h, manually washed with a clean sponge, and subsequently rinsed with DI water 3–5 times

The Schott glasses, caps, glass vials and silicone stoppers were then wrapped in aluminum foil and placed in an oven at 105 °C to dry overnight (8 h +)

VII

Standard laboratory dishwasher (with Extran AP17 liquid detergent)