Skip to main content

Evaluation of indoor daylighting performance changes in a historical khan building in Istanbul

Abstract

The daylighting feature of historical buildings can be accepted as an intangible heritage since it contributes to the unique atmosphere of the buildings. However, with the change of the built environment and the change of the historical building itself, the level of daylight intake of historical buildings changes. This study contributes to the field by revealing the daylighting performance changes of a historical khan building which has a unique architectural characteristics. The changes in the daylighting levels of Buyuk Yeni Khan, one of the largest historical khans in Istanbul, are examined through its modifications. Using 3D Lidar scanning technology, the current state of the khan is scanned. The daylight intake and glare analyzes of the khan for its current and original states are made through simulations, and the values found are compared. DA, cDA, UDI, sDA and DGP metrics are used in the simulations. As a result, due to the changes such as enlargements along the arcades, additional overhangs and the change of window ratios of the facades of the rooms on the ground floor, the rooms of the khan have different daylighting values compared to its original state.

Introduction

Changes in the urban built environment are typically manifested through variations in morphological characteristics, such as alterations in building heights, the shapes of building blocks and the dimensions of plots [1, 2]. Institutional factors such as formal organisations, and natural factors such as natural disasters can lead to change in built environment [3]. As a result of the modifications of the built environment, the indoor environment quality (IEQ) of buildings can change. This situation can greatly affect the IEQ of historical buildings as well. Also, historical buildings may undergo various modifications or restorations [4] that can effect their IEQ. IEQ parameters are accepted as thermal comfort, air quality, lighting and acoustics [5,6,7]. As Che et al. [8] and Ridolfi et al. [9] have done, there are studies that examine how the indoor environmental quality changes as a result of the modifications in buildings and make inferences for future studies. In addition, as Balocco and Calzolari [10], Zhang et al. [11] and Marzouk et al. [12] have done, studies are also carried out on improving IEQ of heritage buildings.

In addition to the studies on improving the energy efficiency and thermal comfort of historical buildings within the scope of IEQ [13], the studies on daylighting analysis and daylight intake control in historical buildings have also accelerated in recent years. For example, there are studies on the suitability of the daylighting level in the new use of historical buildings originally designed for a different purpose [14, 15]. Studies are also carried out to provide light control in order to protect the light sensitive valuable artifacts in the interiors of historical buildings [16,17,18]. There are also studies on the use of daylighting as a design strategy in historical buildings [19,20,21]. In addition, analyzes are made on historical buildings whose daylight intake levels have changed due to the change in the built environment around them [22]. This study also focuses on the daylighting performance change of a historical building.

Daylight intake in buildings affects the visual comfort, productivity and well-being of the occupants [23,24,25,26,27]. In addition, the proper intake of daylight into the space reduces electricity consumption and prevents unnecessary energy consumption [28, 29]. Besides, as Al-Maiyah and Elkadi [30] mentions, daylighting performance is rarely considered when renovating historical buildings. Because if the renovated building takes on a new function, the new daylighting performance of the interior is shaped according to the lighting required by the new function. Also, other performance metrics such as thermal performance and energy performance may be shaped according to a new function or energy retrofit regulations. However, daylighting performance of historical buildings is actually a part of the visual character of these buildings. Daylighting parameters of a building can be defined as the combination of sunlight, skylight and the reflected light from the facades and the ground, and these parameters affect visual perception and the identity of the place, so that it forms visual character of the building [31]. Original visual characteristic of a historical building is a part of its identity. Therefore, this feature can be accepted as an intangible cultural heritage and should be preserved. Additionally, with the advances of UNESCO’s Safeguarding of Intangible Heritage adoption, digitalisation and documentation of intangible cultural heritage is important [32].

The interior space performance changes of historical buildings that have changed over time can be observed by comparing the old and new states of the buildings. In this study, it is focused on the changes of daylighting performance of khan buildings. This paper aims to examine indoor daylighting performance change of Buyuk Yeni Khan by comparing its current and original states. By detecting the changes in daylighting performance of the khan, actions can be taken to improve IEQ in a possible restoration or renovation work. This paper not only emphasizes and quantifies the atmosphere created by daylighting in the khan buildings which have unique architectural characteristics, but also defines the changes of daylighting performance through the time. This study contributes to the literature by providing an analysis of the changes in daylighting performance of historical khan buildings, a topic that has not been previously explored.

Materials and methods

The function of closed areas of the khan and the height of the surrounding buildings have been examined (Fig. 1). Then, the parts of the khan such as semi-open areas (arcades), courtyard and the rooms have been scanned with Lidar 3D scanning technology. After collecting the data from the site, the 3D modeling and daylighting analysis have been done. The model created with Lidar technology was used as a base for 3D modeling. 3D modeling was done in Rhinoceros [33] programme. Daylighting and glare analysis were performed using Grasshopper [34] and Honeybee + Ladybug tools [35]. Honeybee + Ladybug tool uses Radiance, EnergyPlus/OpenStudio, Therm/Window and OpenFOAM programs in the background. For the sensitivity analysis Colibri [36] add-on for Grasshopper was used. Since this study utilizes Rhinoceros for 3D modeling, Grasshopper, which is compatible with Rhinoceros, was chosen as daylighting analysis platform. Additionally, a script was created with the help of add-ons added to Grasshopper. Another reason for choosing the Grasshopper platform for daylighting analysis is its capability to integrate additional IEQ parameters, such as acoustics and thermal comfort, into the script. However, it is important to note that other programs, such as VELUX Daylight Visualizer and LightStanza, can also perform daylighting analysis through modeling.

Fig. 1
figure 1

Framework of the study

Daylight Autonomy (DA), Continous Daylight Autonomy (cDA), Spatial Daylight Autonomy (sDA), Useful Daylight Illuminance (UDI) and Daylight Glare Probability (DGP) metrics were used in the daylighting and glare analysis. DA measures annual (climate-based) indoor daylighting performance based on the location of the buildings and is defined as the percentage of the time that a particular daylight level is exceeded a specified illuminance [37, 38]. When the illuminance level in the space drops below the required threshold, partial credit is allocated to time intervals based on the cDA metric [39, 40]. sDA reports the percentage of floor area in a building that exceeds a specified illuminance level for a specified amount of annual hours [41, 42]. This metric helps understand the distribution of daylight within a space, ensuring that a substantial portion of the area receives adequate natural light for a significant part of the day. UDI defines the percentage of time that daylight levels fall within a “useful” range for a given space [43, 44]. If daylight illuminance falls below 100 lx at a given time, it is insufficient for proper lighting, resulting in an undersupply UDI bin. If it exceeds 2000 lx, it likely causes visual or thermal discomfort, leading to an oversupply UDI bin. If the illuminance is between 100 and 2000 lx, it offers useful lighting levels, resulting in a useful UDI bin. DGP metric is used to measure daylight comfort level of the spaces. DGP levels are as follows: imperceptible (< 0.35), perceptible (0.35–0.40), disturbing (0.40–0.45), intolerable (> 0.45) [45, 46].

Daylighting simulations are done with grouping the rooms according to their sides. The groups are named as the rooms at the North side, the rooms at the South side, the rooms at the West side, the rooms at the East side and the rooms at the Transition area. Glare simulations are done by selecting a room from each side. Sensitivity analyses are also done by taking account of the selected rooms for glare simulations.

Case study

City khans are the places that have been used as shops, warehouses, offices, manufacturing and trade spaces from the past to the present. There could also be city khans with accommodation functions. City khans that did not provide accommodation were called commercial khans [47]. The historical khans include courtyards which are surrounded by semi-open spaces (arcades/revak) and closed rooms. They usually have rectangles or squares in the plans. This building type referred as khans [48,49,50], han [51] or inns [52] in the literature. However, since the word “khan” is used in the UNESCO’s “Bursa and Cumalıkızık: the Birth of the Ottoman Empire” [53] description, the word “khan” used in this study as well.

It is known that in the Ottoman Period, from the fifteenth century to the first quarter of the twentieth century, approximately 300 khans were built and 110 of them are still standing [52, 54]. There are many khans in the historical peninsula of Istanbul, which has been a trade center for many years in the Ottoman period. Since there are many khans located as clusters around the Grand Bazaar in Eminonu, this area is called the khans district [55]. Buyuk Yeni Khan is also located in this region (Fig. 2). Buyuk Yeni Khan is a busier khan compared to other khans in Eminonu district of Istanbul. As Yaşar [56] mentioned, this khan is the one of the largest khan in Istanbul. In this khan, almost all the rooms are in use today. Therefore, Buyuk Yeni Khan has been selected to be examined in this study.

Fig. 2
figure 2

The location of Buyuk Yeni Khan and the neighbourhood area

Buyuk Yeni Khan is located in Taya Hatun district of Eminonu. The location is at the intersection of Cakmakcilar Yokusu Street, Sandalyeciler Street and Carkcilar Street. It is known that Buyuk Yeni Khan was constructed during the period of Sultan Mustafa III [57]. According to the date written in a script on the façade of the khan, it is thought that the built date of the building could be around 1763–1764 [58]. It is also thought that the architect of the khan could be Mehmet Tahir Aga [47].

Buyuk Yeni Khan has a rectangular-like plan shape, and it has three floors covering 5180 m2 [54]. The khan has two courtyards. The main entrance to the khan is from Cakmakcilar Yokusu Street. The first courtyard is 42 m in length, while the second courtyard in the south is 25 m in length. Widths vary between 12–15 m [58]. The building is situated on sloping terrain. According to Goad’s map (1904) and Pervititch’s map (1942) (Fig. 3), there is one more courtyard at the Southern side. However, this part has lost its original character, so that this part was not taken into consideration in this study. There are also materialistic differences between floors. For example, stone material was used for the ground floor, and mixed technique with the use of stone and brick materials was applied for the other two floors [57, 59]. Unlike the other façades, there are six cantilevers at the north façade. As noted by Yasar [58], it is assumed that this façade typology has been designed to receive more daylight to the interior space. Today, the functions of ground floor level rooms of Buyuk Yeni Khan are based on textile. Textile-based shops, handicraft shops for silver and copper are common on the first floor. The functions of the rooms on the second floor are mainly related to the handicrafts for silver, copper, and beads. Since some of the rooms were locked, the functional definitions of the rooms could not be made.

Fig. 3
figure 3

Buyuk Yeni Khan drawing in Charles Edouard Goad’s map (1904) [63] and Jacques Pervititch’s map (1942) [64]

Manufacturing businesses, which were once densely located in the khans area, have now begun to be replaced by wholesale and retail businesses [60]. In particular, craftsmanship as manufacturing businesses in the region is covered within the scope of intangible cultural heritage [61]. While manufacturing businesses in khans decrease and wholesale and retailing come to the fore, spaces of the khans also transforming. This transformation also changes daylighting needs. However, in the original state of the khan buildings, there were ateliers (such as spaces for silver and copper handicrafts) where daylighting was important. Today, ateliers are still exist mostly on the upper floors of the khans. Although Buyuk Yeni Khan has lost its importance in the last decade, it is still considered one of the most important centers of silver craftsmanship in Istanbul [62]. In addition to being a necessity in these spaces, daylight also creates the visual characteristics of the spaces. The architectural design of the khan is shaped to receive light from both the facade and the courtyard.

3D scanning and modelling

The scanning of the interior side of the khan was done with 3D Lidar scanning technology (Fig. 4). An iPhone 13 Pro Max device was used for this process. 3D Lidar is a remote sensing scanning method that measures distances by illuminating a target with laser light. Scans made with 3D Lidar technology generate accurate measurements. With the help of the precise measurements of the scanned building, the 3D model created for daylighting analysis also features accurate dimensions. As a result, realistic daylighting simulations results can be found. The scanning has been done part by part. For the scan of the interior rooms, reference rooms from different sides were selected for each floor (because every room was not open). After completing the scanning of the parts, the scans were combined and saved as an fbx file. Photos of the site were used for the details of the exterior side. Since the model was computationally intense, the mesh model was simplified. Then, the file was transferred to Rhinoceros 3D modeling programme. The created mesh model from 3D scan has been used as a layout for the creation of a 3D model in Rhinoceros. The plan in Pervititch’s map [64] was used as a layout in the 3D model creation process in Rhinoceros (Fig. 3). Güran’s drawing of the North façade of Buyuk Yeni Khan was also used for the creation of the North façade (Fig. 5). The form-based changes have been reflected in the current and original state modelling of the khan.

Fig. 4
figure 4

3D Lidar interior scanning results of the khan’s current state

Fig. 5
figure 5

The North facade of Buyuk Yeni Khan [65]

The current state of the khan and the drawing of the khan in Pervititch map [64] were compared. As mentioned by Sabancioglu [66], it has been known that Pervititch maps have been drawn between 1922–1945 by Jacques Pervititch. According to the comparison, the boundaries of the khan have not been changed. The outer boundaries of the surrounding buildings have not been changed. However, it has been obtained from the in-situ site analysis that the surrounding building on the Northern side has an additional floor, which is approximately 3 m in height (Fig. 6). This surrounding building was originally constructed with stone and brick material. But, the additional floor, which has been marked with red color in Fig. 6, has different material and it is obviously not part of the original design.

Fig. 6
figure 6

The additional floors on the surrounding building have been marked with red color

The historical photos [67,68,69] were examined and compared with the current state. As it can be seen in Fig. 7, no change was observed in the window openings on the North façade of the first and second floors of the khan, nor in the window openings on the east and west façades. In the courtyard of the khan, no change was observed in the window openings and semi-open space (arcades) on the first and second floors. However, it has been determined that there are various changes on the ground floor of the khan (Fig. 7). Changes on the ground floor are reflected in Fig. 7.

Fig. 7
figure 7

A comparison of the original state with the current state of Buyuk Yeni Khan. a The original state of the North façade of the khan [67]. b The original state of the courtyard of the khan [68]. c The original state of the East façade of the khan [69]

The semi-open spaces (arcades) were transformed to rooms on the ground floor level. Therefore, the size of the rooms at the ground floor level has been dramatically changed. These closed semi-open areas have been covered with glass. Therefore, the typology of the room facades in the courtyard has been changed. The rooms are originally covered by vaults (Fig. 8). Vaults are also shown in the plan drawing of the Buyuk Yeni Khan in Gulenaz’s book [47]. However, some of the vaults are not visible in the current state of the khan, and the ceilings of the rooms look flat. In each courtyard, there is one additional closed room (tea room), which is not a part of the original design. Accordingly, 3D models have been created (Fig. 9, Table 1).

Fig. 8
figure 8

The vault coverings of the rooms (extracted from 3D scanning)

Fig. 9
figure 9

Exploded perspective of the modeling of Buyuk Yeni Khan (a) the current state and (b) the original state

Table 1 Modelling details

Daylighting simulations

Figure 10 shows the used daylight analysis script, which has been adopted from Ladybug Tools tutorials [35] and the studies of Agirbas [70, 71] and Roudsari and Pak [72]. For the daylighting analysis simulation, the surrounding buildings, walls, windows, and floors have been defined. The weather file of Istanbul (by epw format) has been imported to the script. The illumination and radiation ranges of the location have been shown in Fig. 11. Figure 9 demonstrates the closed rooms with walls, windows and doors, semi-open spaces, and surrounding buildings in the 3D model. The semi-open area and the building parts rather than the analysed room were defined as the surrounding context, since it has an impact on the daylighting of the rooms. The model was oriented to the North.

Fig. 10
figure 10

Daylighting analysis script

Fig. 11
figure 11

The illumination and radiation ranges of the location

In this study, the visual character of Buyuk Yeni Khan is defined as intangible heritage and the principle of preservation of this visual character is adopted. It is known that Buyuk Yeni Khan in its original state included mostly metalworking ateliers. Although not as much as before, it still maintains this feature today. According to EN 12464–1:2011 (The Indoor Lighting Standard), the minimum illumination value for handicrafts related to metal processing varies between 300–750 lx and illuminance requirement for “offices and writing” is 500 lx. It is envisaged that not very fine metal processing work was carried out in this khan. Therefore, in this study, the threshold for DA was set at 500 lx. Taking into account the various workshop equipment, the height of the sensors in the analysis grid was set to 1 m from the ground. Various sensor heights for daylighting analysis may be preferable for different building functions. For example Noraini [73] used 1.5 m high sensors for performing museum daylighting analysis, Balocco and Volante [74] used various luxmeter heights for different spaces (such as 0.72 m for working surfaces) of a library transformed from a historical church for performing daylighting analysis. The occupancy of the spaces has been set to all year (between 9 a.m. to 5 p.m.) (Table 2).

Table 2 Daylighting simulation presets

In this study, the material properties are kept constant in the daylighting analyzes for the current state and original state of Buyuk Yeni Khan. The material properties of the original state of the khan is preserved as accurately as possible. Limestone is used for wall, ceiling and flooring material, and single glass material for windows. Reflectance value for limestone is determined as 0.5 [75]. Transmittance value of single glass is adopted from Gündoğdu and Kunduraci’s [76] study. Thus, solely the effect of the change in the architectural form of the khan building and its surrounding built environment on daylighting can be measured. It should also be noted that in the current state of the khan, it is not possible to identify the materials in all its rooms, as many rooms are private property and may be closed.

Results

Daylighting analysis results for the current state of Buyuk Yeni Khan

The results of annual DA daylight analysis for the current state of Buyuk Yeni Khan can be found in Fig. 12. The DA, cDA, UDI and sDA results have been calculated for each room. The rooms have been grouped as the rooms at the North side, the rooms at the South side, the rooms at the West side, the rooms at the East side and the rooms at the Transition area (the rooms at the courtyard). Figure 13 demonstrates the schematic grouping of the rooms. Accordingly, Table 3 shows daylighting value of the related group.

Fig. 12
figure 12

Results of the annual DA daylighting analysis for the current state and the original state

Fig. 13
figure 13

Schematic demonstration of grouping the rooms

Table 3 Daylighting analysis results of the current state of Buyuk Yeni Khan

On the ground floor, the DA result is 45.04% for the rooms at North side; 22.46% for the rooms at the South side; 24.00% for the room at the West side; 41.16% for the rooms at the East side and 10.56% for the rooms at the Transition area (Table 3). On the first floor, the DA result is 16.80% for the rooms on the North side; 2.39% for the rooms at the South side; 11.95% for the room at the West side; 22.15% for the rooms at the East side and 9.71% for the rooms at the Transition area. The DA results of the second-floor level are higher than the ground floor level and the first-floor level. On the second floor, the DA result is 51.35% for the rooms at North side; 12.14% for the rooms at the South side; 50.02% for the room at the West side; 62.02% for the rooms at the East side and 38.46% for the rooms at the Transition area. Since the rooms at the Transition area have roof window openings, the DA result values are more than the rooms at the Transition area in the first-floor level. The results for cDA, UDI, sDA and season based daylighting simulations are consistent with these findings (Tables 3, 4).

Table 4 Season based daylighting analysis results of the current state of Buyuk Yeni Khan

Glare analysis have been conducted for selected rooms from the each side. The simulations have been done for the longest day of the year (21 June, Summer) and the shortest day of the year (21 December, Winter). 12 a.m. has been selected for the time period. At the end of the simulations it has been found that DGP values do not show a great difference (Table 5).

Table 5 Glare analysis results of the selected rooms of the current state of Buyuk Yeni Khan

Daylighting analysis results for the original state of the Buyuk Yeni Khan

The results of annual daylight analysis for the original state of Buyuk Yeni Khan can be found in Fig. 12. As it has been done for the current state of the khan, the DA, cDA, UDI and sDA results have been calculated for each room. The rooms have been grouped as the rooms at the North side, the rooms at the South side, the rooms at the West side, the rooms at the East side and the rooms at the Transition area (the rooms at the courtyard). Accordingly, Table 6 shows daylighting value of the related group.

Table 6 Daylighting analysis results of the original state of Buyuk Yeni Khan

On the ground floor, the DA result is 42.38% for the rooms at the North side; 4.09% for the rooms at the South side; 12.98% for the room at the West side; 40.90% for the rooms at the East side and 8.36% for the rooms at the Transition area. On the first floor, the DA result is 18.08% for the rooms at the North side; 2.50% for the rooms at the South side; 15.60% for the room at the West side; 25.00% for the rooms at the East side and 9.76% for the rooms at the Transition area. On the second floor, the DA result is 50.21% for the rooms at the North side; 11.85% for the rooms at the South side; 54.06% for the room at the West side; 62.03% for the rooms at the East side and 38.45% for the rooms at the Transition area. The results for cDA, UDI, sDA and season based daylighting simulations are consistent with these findings (Tables 6, 7).

Table 7 Season based daylighting analysis results of the original state of Buyuk Yeni Khan

Glare analysis have been conducted for selected rooms from the each side. The simulations have been done for the longest day of the year (21 June, Summer) and the shortest day of the year (21 December, Winter). 12 a.m. has been selected for the time period. At the end of the simulations it has been found that DGP values values do not show a great difference (Table 8).

Table 8 Glare analysis results of the selected rooms of the original state of Buyuk Yeni Khan

Discussion

According to the comparison of the current state of the khan with the original state, it seems that the daylighting values of the rooms at the ground floor level have been changed. The sizes of the rooms and the window ratios of their interior and exterior facades (together with the enlargement) on the South side, West side and East side have been dramatically changed. Since these rooms have been enlarged in line with arcades towards the courtyard, and the window ratios of their facades have been enlarged, the daylight intake values in those spaces are higher than the original state of the khan. In the current state, despite the addition of many extra overhangs towards the exterior side and towards the courtyard, there is still an increase in daylighting values (Table 9).

Table 9 A comparison of the daylighting simulation results of the current state of Buyuk Yeni Khan with the daylighting simulation results of the original state of it

On the first floor, the rooms at the North side, East side and West side have more daylight intake in the original state of the khan. This may be because of the change of the level heights of the surrounding buildings at North (Table 9). According to glare simulation results, the glare values at the selected rooms have not greatly changed (Tables 5, 8).

Criteria were determined to measure the sensitivity of the DGP results in the simulation. Accordingly, it was aimed to measure the sensitivity of the DGP value according to glass transmittance. June 21 at 12 a.m. for the selected room at the ground floor level at Western side (current state) was chosen for the sensitivity analysis. Glass transmittance value range was set between 0 and 1. According to this result, it was seen that glass transmittance affected the glare results to a certain extent (Table 10).

Table 10 Sensitivity analysis according to glass transmittance value

Individual simulation of the selected Eastern side room at the ground floor level was also carried out. Accordingly, an increase was observed in DA, cDA and sDA values in the current state of the khan (Table 11, Figs. 14, 15). In addition to the horizontal sensor grids, vertical sensor grids were also used for the daylighting simulation. Vertical sensor grids were located at 2 m behind the exterior facade. According to the results, a decrease was observed in DA, cDA, sDA and UDI values in the current state of the khan (Table 11, Fig. 14). Similar results were obtained in the seasonal simulations (Table 11). The change of the facade from arch to rectangular frame and the additional overhangs mainly caused these results.

Table 11 A comparison of the daylighting simulation results of the current state of the selected room (the Eastern side room at the ground floor level) with the daylighting simulation results of the original state of it
Fig. 14
figure 14

The daylighting simulation results of the selected Eastern side room at the ground floor level with the use of horizontal and vertical sensor grids

Fig. 15
figure 15

A graphical comparison of the DA and DGP simulation results of the current state of the selected room (the Eastern side room at the ground floor level) with the daylighting and glare simulation results of the original state of it

The study has limitations as listed below:

  • Measurements were obtained through simulation rather than in-situ methods. Conducting in-situ measurements could yield more accurate results. Also, as Saraiva et al. [77] did, comparing simulation results with in-situ measurements could lead to determine the accuracy of the simulation method.

  • The materials for both the current and original states were kept constant. More accurate simulation results for the current state could be achieved by specifying materials separately for each room. It was found that different materials were used in the current state (e.g., corridors covered with ceramics). Therefore, in a daylighting comparison based on material changes, the impact on daylighting would likely be more significant.

  • Since the Lidar scanning has 5 m limitation, the model was created part by part. Other 3D scanning techniques that capable of long distance scanning would create more precise models.

  • This study was conducted on the basis of observable changes in the building. There may be other various changes (e.g. material properties of the rooms, physical changes in the rooms) in the building.

  • Other metrics such as Characteristic Daylight Illuminance (CDI) [20] can also be used for daylighting performance measurements.

As Ünlü [1] mentioned, the urban environment may change over time. This change may affect special buildings that are considered as one of the constant elements of urban morphology [78]. In the study of Carlos and Martins [22], it was observed that the daylight condition of a historical building changed due to the new urban environment. Similarly, present study found that alterations in surrounding building height affected the daylighting of the khan building. Additionally, Giorgi and Matracchi [4] state that various modifications might be made to historical buildings. Present study revealed that this situation also affected the daylighting of the historical khan building.

Buyuk Yeni Khan is located in-between “Sultanahmet Urban Archaeological Component Area of World Heritage Site” and “Suleymaniye Mosque and its Associated Component Area of World Heritage Site” [79], both are in Historical Peninsula of Istanbul. In line with the conservation strategic plans, Istanbul Historical Areas Directorate prepared “Istanbul Historic Peninsula Site Management Plan Boundaries” [80] which includes khans area. To preserve intangible daylighting feature of the khans, related actions can also be added to the strategic plan. For example, restrictions can be imposed to maintain the height of the surrounding buildings. Additionally, legal constraints should be established to prevent additions to the rooms of the khan and to ensure the preservation of their original form. Furthermore, maintaining the IEQ of the khan would ensure a healthy working environment for the craftsmen.

Conclusion

The daylighting of Buyuk Yeni Khan, which is still in active use, has been examined within the scope of this study. The study revealed that modifications in the historical khan building and the changes in the built environment caused the daylighting performance changes, which affects the visual characteristics of the khan and visual comfort of the occupants. The North, South, East and West rooms of the khan were grouped and the daylighting levels were examined for their original and current states. The data and evaluations obtained in this study can be used in the possible restoration or renovation works of the khan.

The contributions of the study have been listed below.

  • The current state of the khan has been scanned with 3D Lidar technology. The 3D model of the current state of the khan and the 3D model of the original state of the khan have been prepared according to the 3D scanning data and observations.

  • At the end of the 3D laser scanning and observations, it was determined that the rooms on the ground floor in the current state of the khan were enlarged in line with the arcades, the vaults of ceilings were covered, additional rooms were added to the courtyard, façade typology of the khan has been changed and overhangs to the exterior and interior facades have been added.

  • After performing daylighting simulations of the current state of the khan and the original state of the khan, it has been found that the changes in the khan building caused the daylighting value changes.

Historical khan buildings, which have their own unique architecture, are special buildings in terms of both their function and their atmosphere. Daylighting analysis studies on historical khan buildings have not been conducted before. This paper is the first study in which the atmosphere of historical khan buildings created by daylighting is emphasized and expressed in numerical data. Although Buyuk Yeni Khan is determined as a case study within the scope of this study, similar daylighting analyzes, and comparisons between the results can be made for many other existing khan buildings. Also, in-situ daylighting analysis can be made in order to validate the simulation results.

Availability of data and materials

Data available at https://doi.org/10.6084/m9.figshare.26204969.

References

  1. Ünlü T. Urban change in Mersin: morphological change in Camlıbel. Megaron. 2006;1(4):178–200.

    Google Scholar 

  2. Agirbas A, Ardaman E. A morphological comparison of urban tissues of Trani and Galata. J Archit Urban. 2015;39(4):232–47. https://doi.org/10.3846/20297955.2015.1113899.

    Article  Google Scholar 

  3. Barau AS, Maconachie R, Ludin ANM, Abdulhamid A. Urban morphology dynamics and environmental change in Kano, Nigeria. Land Use Policy. 2015;42:307–17. https://doi.org/10.1016/j.landusepol.2014.08.007.

    Article  Google Scholar 

  4. Giorgi L, Matracchi P. Architectural evolution: modifications, alterations, and restorations through centuries. J Perform Constr Facil. 2017;31(5):04017046. https://doi.org/10.1061/(ASCE)CF.1943-5509.0001014.

    Article  Google Scholar 

  5. Catalina T, Iordache V. IEQ assessment on schools in the design stage. Build Environ. 2012;49:129–40. https://doi.org/10.1016/j.buildenv.2011.09.014.

    Article  Google Scholar 

  6. Kim J, de Dear R. Nonlinear relationships between individual IEQ factors and overall workspace satisfaction. Build Environ. 2012;49:33–40. https://doi.org/10.1016/j.buildenv.2011.09.022.

    Article  Google Scholar 

  7. Lai ACK, Mui KW, Wong LT, Law LY. An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings. Energy Build. 2009;41(9):930–6. https://doi.org/10.1016/j.enbuild.2009.03.016.

    Article  Google Scholar 

  8. Che W, Cao Z, Shi Y, Yu CW. Renewal and upgrading of a courtyard building in the historic and cultural district of Beijing: design concept of ‘multiple coexistence’ and a case study. Indoor Built Environ. 2022;31(2):522–36. https://doi.org/10.1177/1420326X211010359.

    Article  Google Scholar 

  9. Ridolfi S, Crescenzi S, Zeli F, Perilli S, Sfarra S. Evaluation of the heat changes in an ancient church because of restoration works: a microclimatic study supported by thermal images. Indoor Built Environ. 2022;31(2):375–97. https://doi.org/10.1177/1420326X21994625.

    Article  Google Scholar 

  10. Balocco C, Calzolari R. Natural light design for an ancient building: A case study. J Cult Herit. 2008;9(2):172–8. https://doi.org/10.1016/j.culher.2007.07.007.

    Article  Google Scholar 

  11. Zhang Q, Zhai H, Zhang X, Liu F. Simulation analysis and thermal comfort assessment of indoor environment of the heritage building in gate tower. Indoor Built Environ. 2021;30(6):732–44. https://doi.org/10.1177/1420326X20908920.

    Article  Google Scholar 

  12. Marzouk M, ElSharkawy M, Eissa A. Optimizing thermal and visual efficiency using parametric configuration of skylights in heritage buildings. J Build Eng. 2020;31: 101385. https://doi.org/10.1016/j.jobe.2020.101385.

    Article  Google Scholar 

  13. Martínez-Molina A, Tort-Ausina I, Cho A, Vivancos J-L. Energy efficiency and thermal comfort in historic buildings: a review. Renew Sustain Energy Rev. 2016;61:70–85. https://doi.org/10.1016/j.rser.2016.03.018.

    Article  Google Scholar 

  14. Leccese F, Salvadori G, Tambellini G, Kazanasmaz ZT. Application of climate-based daylight simulation to assess lighting conditions of space and artworks in historical buildings: the case study of cetacean gallery of the Monumental Charterhouse of Calci. J Cult Herit. 2020;46:193–206. https://doi.org/10.1016/j.culher.2020.06.010.

    Article  Google Scholar 

  15. Soleimani K, Abdollahzadeh N, Zomorodian ZS. Improving daylight availability in heritage buildings: a case study of below-grade classrooms in Tehran. J Daylighting. 2021;8:120–33. https://doi.org/10.15627/jd.2021.9.

    Article  Google Scholar 

  16. Mohelníková J, Míček D, Floreková S, Selucká A, Dvořák M. Analysis of daylight control in a chateau interior. Buildings. 2018;8(5):68. https://doi.org/10.3390/buildings8050068.

    Article  Google Scholar 

  17. Al-Sallal KA, AbouElhamd AR, Dalmouk MB. UAE heritage buildings converted into museums: evaluation of daylighting effectiveness and potential risks on artifacts and visual comfort. Energy Build. 2018;176:333–59. https://doi.org/10.1016/j.enbuild.2018.06.067.

    Article  Google Scholar 

  18. del Hoyo-Meléndez JM, Mecklenburg MF, Doménech-Carbó MT. An evaluation of daylight distribution as an initial preventive conservation measure at two Smithsonian Institution Museums, Washington DC, USA. J Cult Herit. 2011;12(1):54–64. https://doi.org/10.1016/j.culher.2010.05.003.

    Article  Google Scholar 

  19. Belakehal A, Aoul KT, Farhi A. Daylight as a design strategy in the ottoman mosques of Tunisia and Algeria. Int J Archit Herit. 2016;10(6):688–703. https://doi.org/10.1080/15583058.2015.1020458.

    Article  Google Scholar 

  20. Monteoliva JM, Bellia L, Fragliasso F, Pattini A. Ancient Romans and daylighting: the case of Villa of the mysteries in Pompeii. J Cult Herit. 2020;43:204–18. https://doi.org/10.1016/j.culher.2019.12.008.

    Article  Google Scholar 

  21. Almaiyah S, Elkadi H. Study on the visual performance of a traditional residential neighborhood in old Cairo. J Urban Technol. 2012;19(4):59–86. https://doi.org/10.1080/10630732.2011.649913.

    Article  Google Scholar 

  22. Carlos JS, Martins AMT. Daylight in a Cistercian heritage church in Lisbon: from rural to urban context. J Green Build. 2014;9(3):116–30. https://doi.org/10.3992/1943-4618-9.3.116.

    Article  Google Scholar 

  23. Roulet C-A, Johner N, Foradini F, Bluyssen P, Cox C, De Oliveira FE, Müller B, Aizlewood C. Perceived health and comfort in relation to energy use and building characteristics. Build Res Inf. 2006;34(5):467–74. https://doi.org/10.1080/09613210600822279.

    Article  Google Scholar 

  24. Borisuit A, Linhart F, Scartezzini J-L, Münch M. Effects of realistic office daylighting and electric lighting conditions on visual comfort, alertness and mood. Light Res Technol. 2015;47(2):192–209. https://doi.org/10.1177/1477153514531518.

    Article  Google Scholar 

  25. Ciampi G, Rosato A, Scorpio M, Sibilio S. Daylighting Contribution for energy saving in a historical building. Energy Procedia. 2015;78:1257–62. https://doi.org/10.1016/j.egypro.2015.11.270.

    Article  Google Scholar 

  26. Tang L, Chen S, Liu M, Su C. Influence of full-spectrum lighting on blood pressure, heart rate and visual comfort on young adults. Indoor Built Environ. 2021;30(4):476–86. https://doi.org/10.1177/1420326X19895294.

    Article  Google Scholar 

  27. Hansen EK, Bjørner T, Xylakis E, Pajuste M. An experiment of double dynamic lighting in an office responding to sky and daylight: Perceived effects on comfort, atmosphere and work engagement. Indoor Built Environ. 2022;31(2):355–74. https://doi.org/10.1177/1420326X21991198.

    Article  Google Scholar 

  28. De Luca F, Simson R, Voll H, Kurnitski J. Daylighting and energy performance design for single floor commercial hall buildings. Manag Environ Qual. 2018;29(4):722–39. https://doi.org/10.1108/MEQ-10-2017-0110.

    Article  Google Scholar 

  29. Li H, Wu D, Yuan Y, Zuo L. Evaluation methods of the daylight performance and potential energy saving of tubular daylight guide systems: a review. Indoor Built Environ. 2022;31(2):299–315. https://doi.org/10.1177/1420326X21992419.

    Article  Google Scholar 

  30. Al-Maiyah S, Elkadi H. Turkish D-light: accentuating heritage values with daylight. Proc Inst Civil Eng Eng Hist Herit. 2015;168(4):139–49. https://doi.org/10.1680/jenhh.15.00004.

    Article  Google Scholar 

  31. Al-Maiyah S, Elkadi H. The role of daylight in preserving identities in heritage context. Renew Sustain Energy Rev. 2007;11(7):1544–57. https://doi.org/10.1016/j.rser.2005.11.004.

    Article  Google Scholar 

  32. Hou Y, Kenderdine S, Picca D, Egloff M, Adamou A. Digitizing intangible cultural heritage embodied: state of the art. J Comput Cult Herit. 2022. https://doi.org/10.1145/3494837.

    Article  Google Scholar 

  33. Rhinoceros. www.rhino3d.com/. Accessed 15 Jan 2022.

  34. Grasshopper, algorithmic modeling for Rhino. www.grasshopper3d.com/. Accessed 15 Jan 2022.

  35. Ladybug tools. www.food4rhino.com/app/ladybug-tools. Accessed 15 Jan 2022.

  36. Colibri. https://www.food4rhino.com/en/app/colibri. Accessed 08 June 2024.

  37. Reinhart CF, Walkenhorst O. Validation of dynamic RADIANCE based daylight simulations for a test office with external blinds. Energy Build. 2001;33(7):683–97. https://doi.org/10.1016/S0378-7788(01)00058-5.

    Article  Google Scholar 

  38. Bian Y, Ma Y. Analysis of daylight metrics of side-lit room in canton, south China: a comparison between daylight autonomy and daylight factor. Energy Build. 2017;138:347–54. https://doi.org/10.1016/j.enbuild.2016.12.059.

    Article  Google Scholar 

  39. Rogers Z, Goldman D. Daylighting metric development using daylight autonomy calculations in the sensor placement optimization tool—development report and case studies. Boulder: Architectural Energy Corporation; 2006.

    Google Scholar 

  40. Agirbas A. Performance-based design optimization for minimal surface based form. Archit Sci Rev. 2018;61(6):384–99. https://doi.org/10.1080/00038628.2018.1523130.

    Article  Google Scholar 

  41. IESNA. LM-83-12 IES spatial daylight autonomy (sDA) and annual sunlight exposure (ASE). New York: IESNA; 2012.

    Google Scholar 

  42. Lee J, Boubekri M, Liang F. Impact of building design parameters on daylighting metrics using an analysis, prediction, and optimization approach based on statistical learning technique. Sustainability. 2019;11:1474. https://doi.org/10.3390/su11051474.

    Article  Google Scholar 

  43. Nabil A, Mardaljevic J. Useful daylight illuminances: a replacement for daylight factors. Energy Build. 2006;38(7):905–13. https://doi.org/10.1016/j.enbuild.2006.03.013.

    Article  Google Scholar 

  44. Nabil A, Mardaljevic J. Useful daylight illuminance: a new paradigm for assessing daylight in buildings. Light Res Technol. 2005;37(1):41–57. https://doi.org/10.1191/1365782805li128oa.

    Article  Google Scholar 

  45. Wienold J, Christoffersen J. Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD cameras. Energy Build. 2006;38(7):743–57. https://doi.org/10.1016/j.enbuild.2006.03.017.

    Article  Google Scholar 

  46. Xue Y, Liu W. A study on parametric design method for optimization of daylight in commercial building’s atrium in cold regions. Sustainability. 2022;14:7667. https://doi.org/10.3390/su14137667.

    Article  Google Scholar 

  47. Gulenaz N. Batililasma Donemi Istanbul’unda Hanlar ve Pasajlar. Istanbul: Istanbul Ticaret Odasi Yayinlari; 2011.

    Google Scholar 

  48. Gedik GS, Yıldız D. Assessing the role of users in sustainable revitalization of historic urban quarters: the case of Bursa-Khans District. ITU A|Z J. 2016;13(1):195–208.

    Google Scholar 

  49. Sen S, Arslan TV. The evaluation of space quality in outdoor open spaces: Bursa historical bazaar and Khans District as a Case. Eur J Sustain Dev. 2016;5(3):27. https://doi.org/10.14207/ejsd.2016.v5n3p27.

    Article  Google Scholar 

  50. Arslan TV. Developing a strategic approach for managing sustainable revitalisation in world heritage sites: historical Bazaar and Khans District, Bursa—Turkey. Archnet IJAR Int J Archit Res. 2015;9(1):289–304.

    Article  Google Scholar 

  51. Shakur T, Hafiz R, Arslan TV, Cahantimur A. Economy and culture in transitions: a comparative study of two architectural heritage sites of Bazars and Hans of Bursa and Dhaka. ArchNet-IJAR: Int J Archit Res. 2012;6(3):91–108.

    Google Scholar 

  52. Benli G, Vatan M. The reuse and conservation of Ottoman commercial inns on the Historic Peninsula in Istanbul. Int J Electr Mech Mechatr Eng. 2017;7(1):1355–63.

    Article  Google Scholar 

  53. Bursa and Cumalıkızık: the Birth of the Ottoman Empire, UNESCO. https://whc.unesco.org/en/list/1452/. Accessed 08 June 2024.

  54. Benli G. Istanbul Tarihi Yarimadada Bulunan Han Yapilari ve Avlulu Hanlarin Koruma Sorunlari. PhD Thesis, Yıldız Technical University, İstanbul, 2007.

  55. Ozkan-Ozbek M. Accessibility patterns of Istanbul’s Hans region as a traditional urban trade district. In: Ozcevik O, Brebbia CA, Sener SM, editors. Sustainable development and planning VII. Southampton: WIT Press; 2015. p. 227–37. https://doi.org/10.2495/SDP150191.

    Chapter  Google Scholar 

  56. Yaşar A. 19. Yüzyıl Ortalarında İstanbul’da Hanlar: Mekânsal Bir Analiz. Osmanlı Araştırmaları. 2023;61(61):151–215. https://doi.org/10.18589/oa.1316377.

    Article  Google Scholar 

  57. Eyice S. Buyuk Yeni Han. Istanbul: TDV Islam Ansiklopedisi; 1992. p. 519–519.

    Google Scholar 

  58. Yaşar A. The construction of commercial space in eighteenth-century Istanbul: the case of Büyük Yeni Han. METU J Fac Archit. 2018;35(1):183–200.

    Google Scholar 

  59. Bilecik G. Unutulmaya Yuz Tutmus Bir Ticaret Hani: Yeni Han. Electr Turk Stud. 2017;12(13):71–94.

    Google Scholar 

  60. Şabudak Ö. Osmanlı’dan Günümüze Hanlar Bölgesi’nin Mimari ve İktisadi Dönüşümü. Turk Stud Int Period Lang Lit Hist Turk Turkic. 2014;9(1):509–20. https://doi.org/10.7827/TurkishStudies.6202.

    Article  Google Scholar 

  61. Ökten A, Evren Y. Safeguarding the intangible cultural heritage through a tri-sector model: the jewellery quarter in the old city of Istanbul. Planlama. 2013;23(1):35–44. https://doi.org/10.5505/planlama.2013.03521.

    Article  Google Scholar 

  62. Ökten A, Evren Y. İstanbul’da geleneksel kuyumculuk sektöründe yıkımın coğrafyası: zanaatkâr gözüyle mekân ve yer. 4. Kentsel ve Bölgesel Araştırmalar Ağı Sempozyumu, pp. 652–660. Mersin, 28–30 Kasım; 2013.

  63. Dağdelen İ. Charles Edouard Goad’ın İstanbul Sigorta Haritaları. İstanbul Büyükşehir Belediyesi Kütüphane ve Müzeler Müdürlüğü Yayınları, İstanbul, 2007.

  64. Pervititch J. Sigorta Planı, Eminonu, Tayahatun, No 62. Salt Research archives; 1942. https://archives.saltresearch.org/handle/123456789/119021. Accessed 15 Jan 2022.

  65. Güran C. Türk Hanlarının Gelişimi ve İstanbul Hanları Mimarisi. İstanbul: Vakıflar Genel Müdürlüğü Yayınları; 1976.

    Google Scholar 

  66. Sabancioglu M. Jacques Pervititch and his insurance maps of Istanbul. Dubrovnik Annals. 2003;7:89–98.

    Google Scholar 

  67. Robert L. Van nice collection, image collections and fieldwork archives, Dumbarton Oaks research library and collection. Street scene. Reaccession Number: 2012.0011.0034 http://images.doaks.org/artamonoff/items/show/734. Accessed 15 Jan 2022.

  68. Myron Bement Smith Collection, Freer Gallery of Art and Arthur M. Sackler Gallery Archives, Smithsonian Institution. 1936. View of courtyard looking south at later addition dividing the courtyard in two. Reaccession Number: Artamonoff P115 http://images.doaks.org/artamonoff/items/show/2109. Accessed 15 Jan 2022.

  69. Eski İstanbul Fotoğrafları Arşivi. Buyuk Yeni Han Duvarı 1980. http://www.eskiistanbul.net/arama/b%C3%BCy%C3%BCk-yeni-han. Accessed 15 Jan 2022.

  70. Agirbas A. Multi-objective building design optimisation using acoustics and daylighting. Indoor Built Environ. 2022;31(3):853–67. https://doi.org/10.1177/1420326X211040100.

    Article  Google Scholar 

  71. Agirbas A. Building energy performance of complex forms: test simulation of minimal surface-based form optimization. In: Proceedings of the 38th eCAADe conference; 2020. p. 259–268. https://doi.org/10.52842/conf.ecaade.2020.1.259

  72. Roudsari MS, Pak M. Ladybug: a parametric environmental plugin for grasshopper to help designers create an environmentally- conscious design. In: Proceedings of the 13th international building performance simulation association conference, Chambery, France, 26–28 August 2013. p. 3128–35.

  73. Noraini A, Sabarinah ShA, Anuar T. Luminous exposures and light-fastness survey in daylit historical museum galleries under tropical sky conditions. Adv Mater Res. 2012;488–489:1547–52.

    Google Scholar 

  74. Balocco C, Volante G. A method for sustainable lighting, preventive conservation, energy design and technology—lighting a historical church converted into a university library. Sustainability. 2019;11:3145. https://doi.org/10.3390/su11113145.

    Article  Google Scholar 

  75. E-Light. Material Properties. https://iarc.uncg.edu/elight/learn/determine/lc_sub/mat_prop.html. Accessed 08 June 2024.

  76. Gündoğdu E, Kunduraci AC. Effect of window glazings’ visible transmittance to daylight factor and energy efficiency in an architecture studio. J Emerg Trends Eng Appl Sci. 2019;10(4):171–8.

    Google Scholar 

  77. Saraiva NB, Rodrigues E, Gaspar AR, Costa JJ. Daylighting simulation of a heritage building by comparing matrix methods and solar models. Sol Energy. 2021;224:685–96. https://doi.org/10.1016/j.solener.2021.05.085.

    Article  Google Scholar 

  78. Agirbas A. Macro-scale complex form generation through a swarm intelligence-based model with urban morphology constants. Archit Sci Rev. 2021;64(6):504–21. https://doi.org/10.1080/00038628.2020.177738.

    Article  Google Scholar 

  79. Historic Areas of Istanbul, UNESCO. https://whc.unesco.org/en/list/356/maps/. Accessed 08 June 2024.

  80. Istanbul Historic Peninsula Management Plan, 2018, Historic Areas of Istanbul Site Directorate. http://www.alanbaskanligi.gov.tr/evrak/engtyp.pdf. Accessed 08 June 2024.

Download references

Acknowledgements

Not applicable.

Funding

This research did not receive any funding.

Author information

Authors and Affiliations

Authors

Contributions

AA: conceptualization, methodology, investigation, formal analysis, writing, editing, supervision, visualization; AOD: investigation, in situ analysis, experimental tests and analysis, writing, visualization.

Corresponding author

Correspondence to Asli Agirbas.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Agirbas, A., Dal, A.O. Evaluation of indoor daylighting performance changes in a historical khan building in Istanbul. Herit Sci 12, 313 (2024). https://doi.org/10.1186/s40494-024-01409-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40494-024-01409-9

Keywords